Customization: | Available |
---|---|
Usage: | SMT Production Line, Printing Workshop, Computer Room, Electronic Component Maintenance Room, Combustible & Explosive Area, Lab Equipment |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Work volume | 1725L |
Inner size | 1320mm*1170mm*1120mm W*H*D |
Outer size | 1810mm*2000mm*2000mm W*H*D |
Temp range | -40ºC---+180ºC |
Humidity range | 10%-98%RH |
Temp stability | ±0.5ºC( no load) RH:±2.0% |
Temp uniformity | ±0.2ºC( no load) RH:±2.0% |
control accuracy | 0.01ºC |
Cooling rate | RT- -40ºC/100min 1ºC/min |
Temp rise rate | Rt- +150ºC/50min 3ºC/min |
Outer layer material | High-quality cold-rolled plate spray paint |
Inner layer material | SUS#304 mirror stainless steel plate |
Observation window | 40*50cm rectangular multi-layer vacuum electric heating glass observation window, completely prevent the observation window from condensation |
Insulation Material | High density rigid PU foam and 24K glass wool |
Illumination | LED light |
Inlet test hole | 1 Ø50mm cable hole, installed on the left side of the chamber in case that the test object needs an external power supply or signal. The cable hole made of special materials can withstand high and low temperatures for a long time, and solves the problem of surface condensation during long-term low-temperature tests. , Equipped with a cover of the same material and a silicone plug |
Isothermal board | An isothermal plate is designed on the top of the test box to avoid the problem of condensed water dripping onto the product during the humidity test and causing the product to be scrapped. |
Door | The special design of the test chamber door structure and the sealing strip can effectively keep warm and prevent temperature escaping |
Air pressure balance device | The top of the test box is equipped with an air pressure balance device, which can automatically open and release the pressure when the pressure is too high to ensure that the air pressure in the box is always maintained same with the outside world during the heating, cooling, and constant test. |
Heater | High-quality finned electric heater, no open flame, reasonable design length and installation method, make heating load on the surface even, and the service life is longer. The heater is installed in the air duct. |
Heating control mode | Use non-contact and isocycle pulse width adjustment SSR (solid state relay) to control the heating output, which can effectively adjust the temperature rise and fall process, and avoid the phenomenon of large temperature overshoot |
Overheat protector | An overheat protector is installed in the air duct, when the temperature in the box exceeds the temperature set by the protector,it will alarm and automatically cut off the heater |
Compressor | Tecumseh compressor The design of the refrigeration system applies energy adjustment technology to ensure that the energy consumption and refrigeration capacity of the refrigeration system are effectively adjusted under the normal operation , make operating costs more economical |
Condenser | High-efficiency heat exchange coils, aluminum fins "L"-shaped extension flaps, tight close contact with expansion tube, greatly improving the heat transfer efficiency |
Evaporator | High-performance internally threaded coil, high-performance turbulent aluminum fins |
Heat exchanger | Adopt high-quality brazed plate heat exchanger, all plates are joined together by copper solder, all contact points are completely welded together, to ensure that the heat exchanger has the highest heat exchange efficiency |
The electromagnetic valve | Adopt Danfoss two-way electromagnetic valve, the protection level of the valve coil shell is as high as IP67 to ensure normal operation under various working conditions. |
Oil separator | Using Emerson high-efficiency centrifugal oil separator, the oil return rate is as high as 99%, which can effectively reduce the load of the evaporator and compressor, the pressure reduction design can maximize the flow rate, |
thermal expansion valve | The Danfoss dual-port thermal expansion valve is used to shut off the flow. The expansion valve adjusts the flow rate through the change of the heat at the end of the evaporator to prevent insufficient utilization of the evaporator area and compressor machine knocking |
Pressure controller | Adopt Danfoss single-pole double-throw pressure controller, with system pressure over high alarm, automatic reset function, compact structure design |
Evaporator regulating valve | The Danfoss evaporation pressure regulating valve is used to keep the evaporation pressure of the system constant. through the throttling of the regulator on the suction line, the surface temperature of the evaporator can be controlled to avoid long-term low-temperature, high-humidity or low-temperature and low-humidity tests caused by evaporator icing phenomenon. |
Refrigerant | R404 R23 |
Cooling mode | Air cooling |
Temp sensor | PT100 |
Humidity sensor | PT100 |
Screen resolution | 800*480 |
Setting accuracy | Temp:0.01ºC Humidity: 0.1%RH Time:1s |
Program capacity | 1000 groups, each group can have up to 100 segments, the number of segments required by each group of programs can be divided arbitrarily, and each group of programs can be freely connected to each other |
Program group loop | 999( set 0, infinite loop) |
Program segment loop | 99 |
Instrument setting range | Temperature: -100ºC~+200ºC, Humidity: 0~100%RH Time: When doing program test, each program can be done for up to 999 hours and 59 minutes |
PID | 9 groups each for temperature and humidity |
Power-off memory | With power-off memory function and restart mode when power is restored |
Schedule booting | Schedule the boot time by setting year, month, day and minute |
Operation mode | Program operation, fixed value operation, and connection operation three operation modes |
Backlight | The brightness of backlight is adjustable, and the turn-on time is set according to the test time to achieve the purpose of prolonging the service life |
Interface | Ethernet interface |
The instrument connecting method with the host computer | Direct connection method, LAN network method, Internet method |
Emergency stop switch | Emergency stop switch, in case of equipment accidents |
In-place channel | Can pass according to the outer dimensions of the chamber(note the special links such as corners, entrance dimensions, elevator dimensions, etc.) |
Ground load-bearing | The ground load-bearing requirement of the site ≥600kg/m2 (for the installation site upstairs or vacant underground) |
Site requirements and size required for placement | Maintenance space around the equipment: left and right ≥ 80cm; top ≥ 60cm; front ≥ 145cm; rear ≥ 110cm. The ground is flat, well ventilated, and does not contain flammable, explosive, corrosive gas and dust. There is no strong electromagnetic radiation source nearby.It is best to have a drainage floor drain next to the chamber |
Power | 18KW |
Input voltage | 380V±10%, 50Hz±1 three-phase four-wire + grounding wire, protective grounding resistance is less than 4Ω |
Grounding | Grounding resistance <4Ω, independent grounding, namely TN-S grounding system, using three-phase five-wire AC power supply (mixed use of middle and ground is strictly prohibited) |
Cable | It is recommended to choose a rubber sheathed copper core power cord no less than 3×20mm²+2×10mm² |
Environment | 1, 5~25ºC to ensure the best performance, 25~35ºC can operate normally (for air-cooled test chamber) 2,humidity: ≤85%RH 3, air pressure:86KPa~106KPa |