Customized Face Mas Machine Electrostatic Generator
Operation
1. Grounding: First, ground the output grounding terminal of the DC high-voltage power supply, and ensure that the resistance between the DC high-voltage power supply shell and the ground is less than or equal to 10 Ω.
2. Connect to high voltage: Insert the high-voltage input plug of the ion emitter (rod) into the output socket of the DC high-voltage power supply, and then lock it with the built-in screw on the high-voltage plug.
3. Connect to the power supply: Insert the octagonal plug at the input end of the DC high-voltage power supply into a 220V 50HZ AC mains socket with a ground wire. Turn on the power switch on the DC high-voltage power supply, the indicator light will be on, and adjust the voltage output knob to obtain a suitable DC high-voltage output.
(4) Precautions
1. The charging effect of this ion generator is closely related to the structure and installation of the ion emitter (rod). Generally, the ion emitter (rod) needs to be customized on-site.
2. Do not use this ion generator in flammable and explosive environments.
Attention:
Do not install the high-voltage generator in a damp, dirty, flammable or explosive environment.
-The high-voltage generator must be installed in a place without vibration.
1. The high-voltage generator should be installed in a convenient location and as close as possible to the discharge rod.
2. Use screws to secure the high voltage generator if necessary.
3. Connect the ground wire to the ground post.
4. Connect the plug of the discharge rod to the output jack of the high-voltage generator and lock it with the nut provided.
5. Set the [ON/OFF] switch to the [OFF] position.
6. Plug the power cord connector into the power connector on the back of the high-voltage generator.
7. Insert the power cord plug into a grounded power outlet.