Factory High Effecience Long Working Distance Ionizing Air Curtain

Usage: SMT Production Line, Printing Workshop, Computer Room, Electronic Component Maintenance Room, Combustible & Explosive Area
Nozzle: Replaceable
Length: Optional
Decay Time: 1.0s
Offset Voltage: +-30V
Working Voltage: DC24V
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
EC-600
Condition
New
Waterproof
Non-Waterproof
Type
Ionizing Air Blower
Material
Metal
Transport Package
2kg
Specification
610mm/710mm/810mm/910mm/1010mm/1110mm
Trademark
ECW
Origin
China
HS Code
8543709990
Production Capacity
10000PC

Product Description

Factory High Effecience Long  Working Distance Ionizing Air Curtain

EC-600 ion air curtain is a special device for eliminating static electricity. It has the characteristics of simple installation, stable operation and large elimination of static electricity.


Section 1  Principle of static electricity elimination
The EC-1800 air curtain generates a high voltage, forming a stable high-strength electric field, then ionizes the airflow and produces ions. When the ions with air flow reach the objects surface, neutralizing their static electricity.

The air volume of the device can be adjusted by a speed switch in a wide range. There is a special cleaner on the ionization device to remove the dust on the ionization needle and keep the ionization device working properly.

The EC-1800 ion air curtain has a dedicated ion balance circuit that achieves automatic ion balance. The anti-static function can solve the production problems caused by static electricity, such as solving the problem of dust collection caused by static electricity, the problem of adhesion during processing of plastic products, and the jumping of small parts caused by electrostatic.


Section 2  Product Features

1. Neutralizes static electricity quickly.
2. The ion flow covers a large area.
3. The air volume could be adjusted in a large range.
4. Ionization indicator.
5. The device has good grounding protection.

Section 3  Specification
 
Input voltage 220V/50H or110V/60Hz
Power AC 7.0KV
Ion balance ≤±35V(30cm in front of the Device)
Decay time ≤0.5S (30cm in front of the Device)
Ozone volume <0.03PPM(15cm in front of the Device) 
Working temperature -10ºC~+50ºC 
Dimension  (mm) Power(w)   Flow speed (m/s) (Noise (Db) Weight(kg)
600×190×220 160 11-15 50 11.85
900×190×220 230 11-15 51 15.15
1200×190×220 345 11-15 52 18.45
1500×190×220 390 11-15 53 22.25
1800×190×220 410 11-15 54 26.55
Frame  Steel
Surface treatment coating


     *
The ion balance voltage and static elimination time of the ion air curtain are in compliance with the ESD standard, and the static elimination time is measured from a test voltage of 1000V to 100V.
* Test data is based on the results of the ME268A Electrostatic Tester.
* Test data will vary due to changes in temperature and humidity of the surrounding air

Section 4  Precautions

4.1 Read the operating instructions before installation.
4.2 Reliable grounding must be done before operation.
4.3 The guard plate are not allowed to be inserted foreign objects.
4.4 Do not operate in flammable and explosive environments.
4.5 Do not repair without authorization.

Section 5  Installation

The ion air curtain has a long service life, and the "L" frame is fixed to the side of the device. Use M8 diameter plum screw to install it onto the wanted position. If the work place is a particularly dirty environment, a filter is optional.

The ion air curtain requires 110V, 60Hz/220, 50Hz voltage, and the grounding socket should be a single-phase standard, and the socket has a safety grounding wire.

Section 6  Operation

If the ion air curtain is well connected with right electricity, then press the power button, the device start to work.

To adjust the airflow direction, loosen the bracket plum screw, tilt the device body to adjust the up and down position, and then tighten the bracket screw after adjusting.

The ion air curtain produces an ionized air covering the target area. The neutralization time is determined by various factors. The two most important reasons are the distance and the airflow speed. The ions are constantly neutralized with each other, and the cations and anions are attracted to each other by static electricity to form a transfer of these charges and recombine. High ion flow speeds enable them to neutralize further away, and the greater the airflow speed, the faster the neutralization. When using the device for electronics assembly, the ionized airflow should cover the working area as much as possible, so that the positive and negative charges on the surface of the object can be well neutralized.

Section 7  Maintenance

Maintenance items: cleaning of the emitter, calibration of the ion balance, and correction of the static elimination time. Clean the emitter at least once a week, and regularly correct the ion balance and the static elimination time to ensure the ion air curtain works normally.

7.1 Cleaning of the Ionizing needles
Use anti-static brushes to clean the ionizing needles at least once a week.

7.2 Air inlet and outlet cleaning
The air inlet and ionization outlets should be kept clean in order to maintain the effect of static elimination and can be cleaned with a soft brush or compressed air.

7.3 Ion balance test
Use a plate static field tester to measure, or use a portable tester to measure ion balance (residual voltage).

7.4 Static elimination time test
Use static analyzer or a plate static field tester to measure static elimination time.

7.5 Calibration
The ion air curtain output design for the ion volume is smooth and fixed. The offset (residual voltage) of the ion balance is formed due to factors such as voltage fluctuations, ambient air dryness, and the like.
Offset standard: 0V ± 35V.

Section 8  Warranty and Service

1.The warranty period is one year. We will repair the products free of charge due to the quality problems caused by the product's own parts, materials and process problems within one year from the date of sale.
2. After the maintenance period
After the maintenance period of the products sold by us, we are still responsible for repairing the labor of the products to protect the our customers' interest.

Factory High Effecience Long Working Distance Ionizing Air Curtain


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Plant Area
>2000 square meters
Management System Certification
ISO 9001