Walk-in Humidity Test Chamber High and Low Temperature Aging Room

Product Details
Customization: Available
Usage: SMT Production Line, Printing Workshop, Computer Room, Electronic Component Maintenance Room, Combustible & Explosive Area, Lab Equipment
Condition: New
Gold Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
>2000 square meters
Management System Certification
ISO 9001
  • Walk-in Humidity Test Chamber High and Low Temperature Aging Room
  • Walk-in Humidity Test Chamber High and Low Temperature Aging Room
  • Walk-in Humidity Test Chamber High and Low Temperature Aging Room
  • Walk-in Humidity Test Chamber High and Low Temperature Aging Room
  • Walk-in Humidity Test Chamber High and Low Temperature Aging Room
  • Walk-in Humidity Test Chamber High and Low Temperature Aging Room
Find Similar Products

Basic Info.

Model NO.
T-12
Waterproof
Non-Waterproof
Material
Metal
Type
Test Chamber
Transport Package
Customized
Specification
Customized
Trademark
ECW
Origin
China
HS Code
8514109000
Production Capacity
100000PC

Product Description

Product name Burn-in-room
Size Inner: W1000*H250*D1000cm
Outer:W1060*H260*D1020cm(excluding control box and motor, control box can be placed as required)
Temperature range 30ºC~+60ºC
Temperature fluctuation ≤±0.5ºC( no load)    
Temperature deviation ≤±2ºC(no load)
Temperature uniformity 2ºC(no Load)
Temperature rise and fall rate 0.8-1.5ºC/min (Non-linear temperature rise and fall at no load)
Heat load capacity 80KW electric heat at 35ºC
Noise 65dB
Floor load capacity 300kg/sqm
Material Inner box material: SUS 304 heat- and hardy stainless steel plate.
Outer box material: 0.8mm high-tension color steel plate  material;
The top keel:hoisted and supported to prevent long-term use of deformation;
Insulation material: high - density glass cotton and high - strength PU foam insulation material
Double-layer temperature-resistant high-temperature tightness
Cooling system The refrigeration system: composed of a semi-hermetic low-temperature compressor. The compressor has the characteristics of compact structure, low vibration, low noise, high energy efficiency ratio, and large cooling capacity under low temperature conditions. The optimized design of the refrigeration system reduced operating costs and increased reliability.
Compressor cooling method:  water-cooled
Air ventilation The centrifugal fan sends air horizontally, and adopts the design of left and right air outlet and middle return air. It is most suitable for the aging of test items in the room, which can effectively take away the heat of the test items themselves. The wind speed and wind pressure meet the test standards, and the temperature stabilizes quickly at the moment of opening and closing the door, ensuring uniform indoor temperature.
Illumination High-brightness and energy-saving LED explosion-proof lamp 40W/AC220V (approximately one electric lamp is arranged for every 8-10 square meters of ceiling area, and the indoor brightness can reach more than 100LUX
Door Electric door 120 x 210(WxH) CM
 safety Gate Escape Gate (90 x 210)CM
 Pressure balance control valve with inner and outer box
Window Multi-layer vacuum glass window W400*H700mm
Control panel Temperature controller, control power switch, (operation, test termination, over-temperature) three-color status indicator, buzzer, exhaust indicator, lighting switch, over-temperature protector, three-phase current indicator, voltage indicator, Voltage changeover switch, etc.
The installation position of the control panel varies with the installation position of the door; the three-color indicator light can be installed separately in crowded areas, so that the relevant personnel can react quickly when the laboratory alarms.(The specific position of the control panel and the three-color indicator light is based on the design drawing)
Power distribution control cabinet Cooling fan switchboard
Main power air switch
The electrical control design refers to the " Design of Low-Voltage Power Distribution" GB50054-95, " Design of Power Supply and Distribution" GB50052, "Construction and Acceptance of Grounding Devices of Electrical Installation Engineering" GB50169-92

All electronic control components and circuits are equipped with markings and wire numbers to standardize electrical assembly and facilitate inspection and maintenance:

 
Heating System Finned radiator tube nickel-chromium alloy U-shaped high-efficiency heater, automatic calculation of high-precision PID+SSR control (calculation cycle: 1~4S can be set), so that the heat loss is equivalent to the heating capacity, Heater control mode: non-contact and other periodic pulse width adjustment, SSR (solid state relay)
 
Control system 7-inch color touch screen with Chinese/English display + German Siemens control module. The controller adopts LCD color touch screen, and the control system adopts man-machine dialogue; it has an automatic, intelligent and humanized design. The control system adopts a two-way input and two-way output control mode to control the temperature, and can display the operating time, the working status of the heater, the refrigeration unit, and the fan. The heating system, refrigeration system, circulation fan and other subsystems can be automatically combined to ensure the high control quality of the entire temperature control system; the control system also has self-detection and self-diagnosis functions, and automatically displays faults and alarms.
RS-232 communication interface software. The system software is designed based on the Windows platform, and has a wide range of adaptability, security, reliability and advancement with other software and hardware. The display screen can directly display and set various operating parameters, operating time, working status of the refrigeration unit and heating system.
It can automatically and timely record temperature data, It is recorded and stored in the host computer in the form of an excel spreadsheet, which can record and save each test data for a long time and large capacity for analysis, sorting and printing at any time. The main performance indicators of TEMP temperature programmable controller:
.Accuracy: Temperature ±0.1%+1digit F.S.
.Resolution:Temperature 0.1ºC
.Temperature slope: 0.1~9.9ºC can be set
.With upper and lower limit standby and alarm function
.Two temperature input signal options, PT 100Ω or mv two options
.Temperature conversion output: 10mv/1ºC
.3 groups of P.I.D control parameter settings, P.I.D automatic calculation
 Screen display function:
.Use screen dialogue, no key input is required, the screen directly touches the options
.The temperature setting (SV) and actual (PV) value are directly displayed
.Can display the current execution program number, segment number, remaining time and cycle times
.Run cumulative time function
.The temperature program setting value is displayed in a graphic curve, with real-time display program curve execution function
.With a separate program editing screen, each page can enter 5 segments of temperature, humidity, time
. Fixed-point or program action status display
.The screen can be adjusted for backlight
The screen display protection function can be set to timer, TIMER or manual shutdown
 Program capacity and control function:
.Amount of programs that can be used: up to 120 groups
.Available memory capacity: 1200 SEGMENTS
.Commands can be executed repeatedly: each command can be up to 999 times
.The production of the program adopts dialogue style, with editing, clearing, inserting and other functions
.With 2 sets of time signal output control (can control the ON/OFF action of the DUT)
.During program execution, it has the function of skipping and holding
.SEGMENT time setting 0~99Hr59min.
With power-off program memory, it will automatically start and continue to execute the program after power is restored
.With RS-232C communication interface and USB interface
The graph curve can be displayed in real time when the program is executed
.With scheduled start-up and shutdown function
.With date and time adjustment function
.Key and screen lock (LOCK) function
Alarm function The equipment is equipped with alarm functions such as over-temperature protection, motor over-heat protection, over-current protection, over-under-voltage alarm, input abnormal alarm, temperature probe abnormality, etc. The alarm mode is buzzer sound and light alarm, sound
Safety protection Leakage circuit breakers;
Door anti-lock protection device "in the room" prompt light.
Over temperature protector
Zero-crossing gate fluid power controller heater air burning prevention protector under-phase reverse phase protection switch
Compressor high pressure protection switch Compressor overheat protection switch Compressor overcurrent protection switch No fuse switch
Ceramic fast fuse
Cable One five-core (four-core cable + protective grounding wire) cable (5 meters long); a set of fuses (vulnerable
Installation place condition The ground is flat, well ventilated, free of flammable, explosive, corrosive gas and dust. There is no strong electromagnetic radiation source nearby.
Ground load-bearing capacity of the site: not less than 300kg/m2
Leave proper maintenance space around the equipment
Environment condition Temperature: 5ºC~35ºC; Relative humidity: 85%RH; Air pressure: 86~106kpa
Input voltage AC380V three-phase four-wire + protective ground wire;
Allowable voltage fluctuation range: AC (1±10%) 380V Allowable frequency fluctuation range: (1±1%) 60Hz
The grounding resistance of the protective earth wire is less than 4Ω; TN-S power supply or TT power supply
Configure an air or power switch with corresponding capacity for the equipment at the installation site, and this switch is independent and dedicated to the use of this equipment. Our company is responsible for the connection of the water source and power supply outside the equipment
Power The total power is about 140.0KW (the actual operating output power after stabilization is about 60% or less of the total power, not including the power consumption of the trolley)
Max current 212.0A
Power switch 300A
Room connect cable 4×75.0mm2+ 1×50.0mm2
Storage temperature 0-45ºC
Training Free training of  operation and maintenance personnel   (location: at company site)
Warranty 2years
Walk-in Humidity Test Chamber High and Low Temperature Aging RoomWalk-in Humidity Test Chamber High and Low Temperature Aging RoomWalk-in Humidity Test Chamber High and Low Temperature Aging RoomWalk-in Humidity Test Chamber High and Low Temperature Aging Room

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now