Customization: | Available |
---|---|
Certification: | CE, ISO, RoHS |
Usage: | Combustible & Explosive Area, Computer Room, Electronic Component Maintenance Room, Printing Workshop, SMT Production Line |
Still deciding? Get samples of US$ 150/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
E-DNS01 Antitatic ESD Anti-Static Sensor Ionizing Air Nozzle, Nozzle Ionizer
Features
1, Inductive Nozzle. Electrical and gas system work synchronously
More suitable for assembly line operation, saving gas source, sensing distance can be adjusted according to product characteristics (up to 1m)
2, It is now possible to transport ions with hoses or metal tubes.
Static electricity can be removed even where the big static eliminator cannot be installed
3, Built-in small high-voltage power supply, can use low-voltage DC power supply
No need special high-voltage power supply or high-voltage cable, no high-voltage failure of the exposed wiring
4, It can accurately eliminate static electricity on the target point
Minimum distance to charged objects up to 1mm, adjustable distance
5, With excellent ion balance, can remove static electricity for a long time
At a distance of 200mm, the decay time from ±1000V to ±100V is less than 1S
(When using standard nozzle or silencer nozzle, apply 0.3MPa)
6, The alarm will be output when an abnormal high voltage system generates ions
Red light is static electricity abnormal operation indicator, green light is static electricity normal operation indicator
7, Can choose a variety of different nozzles
According to the static elimination requirements to choose the right nozzle, so that it can do more with less, nozzle can also be customized according to customer requirements
Installation and Operating
1. Choose suitable accessories in various application.
Install with four screws on the base of ionizer as close to the position of socket as possible. Connect the casing of ionizer to ground socket properly. (This equipment has special earth terminal and can fix to the installing hole).
2. Connect the input air tube, output air tube and power properly and make sure the device is properly targeted at the parts required to have the static eliminated.
3. Install an air filter or electromagnetic valve in front of the input tube.
4.The green light will be on when the power is plugged in. It's normal that the red light is off or dim.
Caution